Find V, U, H & S in the “US” unit system for compressed water with a temperature of 675 F and pressure of 5000 psia.
PHASE: Compressed Water
UNITS: US
Given T675 P5000
Find V, V=0.025082 (T=675 P=5000)
U, U=684.6690 (T=675 P=5000)
H, H=707.8762 (T=675 P=5000)
S, S=0.8820 (T=675 P=5000)
Find P, H & S in the “US” unit system for a compressed water with a specific volume of 0.02 ft3/lbm and temperature of 500 F.
PHASE: Compressed Water
UNITS: US
Given T500 V0.02
Find P, P=2731.4560 (T=500 V=0.02)
H, H=487.5038 (T=500 V=0.02)
S, S=0.6806 (T=500 V=0.02)
Find P, H & S in the “US” unit system for a compressed water with a specific internal energy of 584 Btu/lbm and temperature of 600 F.
PHASE: Compressed Water
UNITS: US
Given T600 U584
Find P, P=5059.4457 (T=600 U=584)
H, H=604.5193 (T=600 U=584)
S, S=0.7876 (T=600 U=584)
Find P & S in the “US” unit system for a compressed water with a specific enthalpy of 170 Btu/lbm and temperature of 200 F.
PHASE: Compressed Water
UNITS: US
Given T200 H170
Find P, P=854.8710 (T=200 H=170)
S, S=0.2930 (T=200 H=170)
Find P & H in the “US” unit system for a compressed water with temperature of 400 F and a specific entropy of 0.566 Btu/lbm-R.
PHASE: Compressed Water
UNITS: US
Given T400 S0.566
Find P, P=499.3813 (T=400 S=0.566)
H, H=375.3790 (T=400 S=0.566)
Find T, H & S in the “US” unit system for compressed water with a specific volume of 0.016 ft3/lbm at 10000 psia,
PHASE: Compressed Water
UNITS: US
Given P10000 V0.016
Find T, T=173.5993 (P=10000 V=0.016)
H, H=165.2224 (P=10000 V=0.016)
S, S=0.2430 (P=10000 V=0.016)