Find T in “F” for a wet steam of 82% quality and specific enthalpy of 960 Btu/lbm.
PHASE: Water-Steam Mix
UNITS: US
Given X0.82 H960
Find Low Temperature T, T=180.0837 (X=0.82 H=960)
Find High Temperature T, T=700.8577 (X=0.82 H=960)
Find T & P in the “US” unit system for a wet steam of 95% quality and specific entropy of 1.8 Btu/lbm-R.
PHASE: Water-Steam Mix
UNITS: US
Given X0.95 S1.8
Find T, T=142.5511 (X=0.95 S=1.8)
P, P=3.0841 (X=0.95 S=1.8)
Find H, S & X in the “US” unit system for a wet steam of 5 ft3/lbm specific volume and 930 Btu/lbm specific internal energy.
PHASE: Water-Steam Mix
UNITS: US
Given V5 U930
Find H, H=993.8781 (V=5 U=930)
S, S=1.3879 (V=5 U=930)
X, X=0.7948 (V=5 U=930)
Find T, P & X in the “US” unit systemor a wet steam of 10 ft3/lbm specific volume and 1100 Btu/lbm specific enthalpy.
PHASE: Water-Steam Mix
Given V10 H1100
Find T, T=265.4331 (V=10 H=1100)
P, P=38.8115 (V=10 H=1100)
X, X=0.9260 (V=10 H=1100).
Find T, P, & X in the “US” unit system for a wet steam of 12 ft3/lbm specific volume and 0.9 Btu/lbm-R specific entropy.
PHASE: Water-Steam Mix
UNITS: US
Given: V12 S0.9
Find T, T=207.0358 (V=12 S=0.9)
P, P=13.3068 (V=12 S=0.9)
X, X=0.4077 (V=12 S=0.9)
Find T, P & X in the “US” unit system for a wet steam of 1000 Btu/lbm specific internal energy and 1055 Btu/lbm specific enthalpy.
PHASE: Water-Steam Mix
UNITS: US
Given U1000 H1055
Find T, T=671.7543 (U=1000 H=1055)
P, P=2562.3857 (U=1000 H=1055)
X, X=0.9094 (U=1000 H=1055)